This is a summary of an inspection on October 13, 2025, not a current assessment. Conditions may have changed since then. It is not a warranty, guarantee, or substitute for a current home inspection. The inspector's full written report is the complete record.
Condition at a glance
5 safety items to address first, 28 repair items, 2 notes.
Foundation & Structure
Action needed
1 safety, 7 repair, 1 note
Exterior & Windows
Action needed
1 safety, 8 repair
Electrical
Action needed
1 safety, 1 repair
Plumbing & Water Heater
Action needed
1 safety, 4 repair
Appliances
Action needed
1 safety, 3 repair
In plain language
The inspection found multiple items needing attention across several systems. Priority should go to electrical safety concerns, foundation movement patterns, and water heater issues. Most other systems have repair needs rather than safety issues.
Foundation. The post-tension foundation shows signs of seasonal movement, which is typical for this region. Cracks and corner pops in the garage are present at several locations.
Major equipment
Furnace
Not specified Not specified · Not specified · gas
6 yrs old at inspection
made 2019
Air conditioner
Not specified Not specified · 3.5 tons · electric · 14-16 SEER · R410A
6 yrs old at inspection
made 2019
Water heater
Not specified Not specified · 50 gallons · gas
6 yrs old at inspection
made 2019
Electrical panel
Eaton / Cutler Hammer Not specified · 200 amps · electric
Year not recorded in this inspection
Known-issue checks
16 checks against the processed portion of this report: panel brands, wiring, pipe materials, gas line bonding, refrigerant, equipment age and construction era.
None of these issues were noted in this inspection.
16 other checks: not noted in this report
- ·Federal Pacific, Zinsco, Challenger or Pushmatic panel
- ·Aluminum branch wiring
- ·Knob-and-tube wiring
- ·Polybutylene supply plumbing
- ·Galvanized steel supply pipe
- ·Cast iron drain lines
- ·CSST gas line bonding
- ·Possible asbestos-containing material
- ·R-22 refrigerant system
- ·Foundation movement opinion
- ·Water heater past typical service life (12 years)
- ·Air conditioner past typical service life (18 years)
- ·Furnace past typical service life (20 years)
- ·Built before 1978 (lead-based paint era)
- ·Built 1965 to 1973 (aluminum wiring era)
- ·Built 1978 to 1995 (polybutylene era)
Public records
Government data for this address, shown next to the inspection. Texas does not disclose sale prices, so none appear here.
Property record
- Year built
- 2019
- Living area
- 1,805 sq ft
- Lot
- 4,400 sq ft
- Appraised 2026
- $574,313 (prior $560,845)
- Last deed transfer
- Oct 2025
Source: Collin Central Appraisal District · as of Oct 2026
Flood and area
- FEMA flood zone
- X · minimal risk
- FIRM panel
- 48085C0482K · effective Nov 2024
- Nearest fire station
- 1.5 mi · Dallas Fire and Rescue Station 13
- Superfund (National Priorities List) sites within 1 mi
- 0
- EPA-regulated facilities within ½ mi
- 25
- EPA radon zone
- 3 · lowest; EPA still recommends testing
Sources: FEMA National Flood Hazard Layer, USGS National Map, EPA Facility Registry, EPA radon zones · as of Oct 2026
Building permits
issued permits only · since Jan 2018May 2026
Residential Accessory Structure Permit · Custom Swing Gate - Dualmetal frame 16F opening total 6F high 2x 4" 1/4" wall hanging post posts will be placed 3-4 fit in ground heavy dut…
IssuedInspected October 13, 2025
Aug 2019
Lawn Sprinkler (LS) Single Family Alteration · INSTALL LAWN SPRINKLER
M.L. JOHNSON & ASSOC. INC PO BOX
IssuedApr 2019
Building (BU) Single Family New Construction · CONSTRUCT NEW SFD
BEAZER HOMES
Issued
Source: City of Dallas open-data permit feed · as of Oct 2026. Issued permits from the City of Dallas open-data feed; the city does not publish inspection status in this feed.
The five major systems
Safety and repair items are shown. Inspector notes are a click away under each system.
Foundation & Structure
1 safety, 7 repair, 1 note
Settlement cracks and corner pops in garage; exposed footings and drainage issues; trees overhead; termite bait stations present.
- Safety
The handrail on the stairway does not run continuously along the full length of the stairs.
Stairways (Interior and Exterior)
- Repair
Cracks in the concrete foundation are visible in several locations in the garage, indicating settlement.
Foundations - Garage · Several Locations
- Repair
A corner pop—a small break or spall in the concrete—was found in the garage foundation.
Foundations - Garage · Several Locations
- Repair
Roof granules are present in the gutters, which can indicate wear on the roofing material.
Grading and Drainage · Several Locations
- Repair
Soil erosion is occurring at the gutter downspouts in several locations.
Grading and Drainage · Several Locations
- Repair
The foundation footing is partially exposed above ground level.
Grading and Drainage · Several Locations
Show 2 more repair items
- Repair
Trees are growing over the front right portion of the house.
Other - Structural · Front Right
- Repair
Wasps are present on or around the property.
Other - Structural
Show 1 note
- Note
Termite bait stations have been installed on the property.
Other - Structural
Exposed fasteners found in several locations on roof structures.
- Repair
Fasteners on the roof structure are exposed in several locations.
Roof Structures and Attics · Several Locations
Electrical
1 safety, 1 repair
Arc fault breakers did not trip when tested; kitchen and hall lights did not activate.
- Safety
Arc fault circuit breaker (AFCI) devices did not respond when tested.
Branch Circuits, Connected Devices, and Fixtures
- Repair
Lights in the kitchen and hallway did not turn on.
Branch Circuits, Connected Devices, and Fixtures · Kitchen/Hall
Heating & Cooling
3 repair
Condenser suction line insulation damaged; thermostat loose; air filter door not sealed properly.
- Repair
The suction line insulation at the outdoor air conditioning condenser is damaged or missing.
Cooling Equipment · Outdoor condensing unit
- Repair
The thermostat is loose and not securely fastened to the wall.
Duct Systems, Chases, and Vents
- Repair
The air filter door does not seal properly.
Duct Systems, Chases, and Vents
Plumbing & Water Heater
1 safety, 4 repair
Water heater TPR valve stuck; shower diverter faulty; gas piping not bonded; sink seal and stopper need attention.
- Safety
The temperature and pressure relief (TPR) valve on the water heater is stuck.
Water Heating Equipment
- Repair
The seal under the mounted sink needs to be addressed.
Drains, Wastes, and Vents
- Repair
The gas piping is not bonded for electrical continuity.
Gas Distribution Systems and Gas Appliances
- Repair
The shower diverter is not functioning properly.
Plumbing Supply, Distribution Systems, and Fixtures
- Repair
The water heater drain stopper did not function as intended.
Water Heating Equipment
Everything elseExterior & Windows, Interior, Appliances, Other Systems: 2 safety, 12 repair, 1 note
Exterior & Windows
1 safety, 8 repair
Cracks in exterior walls and interior wall fractures; window caulk joint cracks and deteriorated mortar at ledges; damaged blinds.
- Safety
The garage door does not have the self-closing feature enabled.
Doors (Interior and Exterior) · Garage
- Repair
The caulk joint at the garage door seal needs attention.
Doors (Interior and Exterior) · Several Locations
- Repair
The bathroom door does not swing properly, either staying open or closed when it should not.
Doors (Interior and Exterior) · Bathroom
- Repair
Cracks are present in the exterior walls in several locations.
Walls (Interior and Exterior) · Several Locations
- Repair
Fractures were found in interior walls.
Walls (Interior and Exterior)
- Repair
Nail pops—raised nails in drywall—are visible on walls.
Walls (Interior and Exterior)
Show 3 more repair items
- Repair
Cracks are present at the interior window caulk joints in numerous locations.
Windows · Numerous Locations
- Repair
Mortar at window ledges has deteriorated in several locations.
Windows · Several Locations
- Repair
Window blinds are damaged.
Windows · Several Locations
Garage ceiling tape joint has a crack.
- Repair
A crack is visible at the tape joint on the garage ceiling.
Ceilings and Floors · Garage
Appliances
1 safety, 3 repair
Dryer vent has lint accumulation; dishwasher trays rusted; bathroom fans loose; range hood light inoperative.
- Safety
Lint is accumulating in the dryer vent.
Dryer Exhaust Systems
- Repair
Rust is visible on the dishwasher trays.
Dishwasher
- Repair
The exhaust fan is loose and not securely attached.
Mechanical Exhaust Vents and Bathroom Heaters · Several Locations
- Repair
The range hood light does not turn on.
Range Hood and Exhaust Systems
Backflow prevention device location not identified for sprinkler system.
1 note from the inspector
- Note
The backflow prevention device for the irrigation system is not located in an accessible area.
Landscape Irrigation (Sprinkler) Systems
Inspections on file
October 13, 2025
Full inspectionThis summary was built from an earlier parse of the report; some later sections may not be included.
Summary prepared by House Report from the inspector's report. House Report Property Intelligence · gethousereport.com
Instant. Opens as a link; no account needed for whoever you send it to. Print or save as PDF. Other sample areas:
Fort Worth, Collin County, Denton County, Austin, Houston, San Antonio.